Describe the intake
Open intake or beach well, feed TDS, temperature range, SDI and known organic or biological risk.
Seawater Desalination RO
OV-SW elements are engineered for seawater, sub-seawater and high-salinity brackish water. LE, HR, FR, XLE and XHR options allow engineers to balance productivity, rejection and fouling resistance across desalination duties.
Product Advantages
Typical Applications
Typical Properties
Values are based on the defined test conditions below. Actual system performance depends on feed-water quality, pressure, temperature, recovery and pretreatment.
| Model | Stabilized rejection | Minimum rejection | Permeate flow | Active membrane area |
|---|---|---|---|---|
| OV-SW-2521 | 99.7% | 99.6% | 300 GPD (1.1 m3/d) | 14 ft2 (1.3 m2) |
| OV-SW-2540 | 99.7% | 99.6% | 600 GPD (2.3 m3/d) | 30 ft2 (2.8 m2) |
| OV-SW-4040-LE | 99.8% | 99.6% | 1,900 GPD (7.2 m3/d) | 90 ft2 (8.4 m2) |
| OV-SW-4040-HR | 99.8% | 99.7% | 1,600 GPD (6.1 m3/d) | 90 ft2 (8.4 m2) |
| OV-SW-8040-LE 400 | 99.8% | 99.6% | 9,000 GPD (34.0 m3/d) | 400 ft2 (37.2 m2) |
| OV-SW-8040-HR 400 | 99.8% | 99.7% | 7,500 GPD (28.4 m3/d) | 400 ft2 (37.2 m2) |
| OV-SW-8040-LE 440 | 99.8% | 99.6% | 9,900 GPD (37.4 m3/d) | 440 ft2 (40.9 m2) |
| OV-SW-8040-XHR 400 | 99.85% | 99.75% | 7,000 GPD (26.5 m3/d) | 400 ft2 (37.2 m2) |
Standard Test Conditions
Operating & Cleaning Limits
Technical Document
Download the original technical sheet used for the model data on this page.
Project Evaluation
OV-SW low-energy, high-rejection and fouling-resistant models are not interchangeable. Selection depends on the intake, salinity, temperature, pretreatment, recovery and target permeate quality.
Open intake or beach well, feed TDS, temperature range, SDI and known organic or biological risk.
Required permeate flow, target water quality, design recovery, operating pressure and vessel configuration.
Review the selected model's published test conditions, membrane area, pressure limit and cleaning limits.
Confirm the final model against system design calculations and the approved technical datasheet before ordering.
For a Useful Quotation
Include the current membrane model if this is a replacement project, plus quantity, destination country and any documentation or private-label requirements. Availability and commercial terms are confirmed with the quotation.
Provide the seawater analysis, temperature, design pressure, recovery, target permeate quality, element size and quantity before selecting an SWRO model.
Technical Inquiry