High-flow Residential & Commercial
High-flow compact elements for commercial RO equipment.
OV-ULP 3012, 3013, 3213 and 4013 elements bridge high-flow household and compact commercial systems. These blue encapsulated elements are not industrial 4040 or 8040 membranes; they are designed for space-efficient purifiers and light commercial equipment.
Product Advantages
Designed around the application.
- 300-2,000 GPD model range
- Integrated compact construction
- Low-pressure operation
- OEM dimensions, label and packaging support
Typical Applications
- Office and restaurant RO systems
- High-flow household purifiers
- Hospital and laboratory equipment
- Compact commercial water systems
Typical Properties
Model performance data.
Values are based on the defined test conditions below. Actual system performance depends on feed-water quality, pressure, temperature, recovery and pretreatment.
| Model | Stabilized rejection | Minimum rejection | Permeate flow | Active membrane area |
|---|---|---|---|---|
| OV-ULP3012-300 | 97.0% | - | 300 GPD (1.14 m3/d) | - |
| OV-ULP3012-400 | 95.0% | - | 400 GPD (1.52 m3/d) | - |
| OV-ULP3012-600 | 93.0% | - | 600 GPD (2.28 m3/d) | - |
| OV-ULP3013-600 | 93.0% | - | 600 GPD (2.28 m3/d) | - |
| OV-ULP3013-1000 | 93.0% | - | 1,000 GPD (3.78 m3/d) | - |
| OV-ULP3213-1200 | 93.0% | - | 1,200 GPD (4.54 m3/d) | - |
| OV-ULP4013-1600 | 93.0% | - | 1,600 GPD (6.05 m3/d) | - |
| OV-ULP4013-2000 | 91.0% | - | 2,000 GPD (7.57 m3/d) | - |
Standard Test Conditions
Test pressure100 psi (0.69 MPa)
Feed concentration500 ppm
Feed temperature25 C
Single-element recovery68-70%
Operating & Cleaning Limits
Maximum operating pressure300 psi (2.07 MPa)
Maximum feed temperature45 C
Maximum feed SDI155
Free chlorine tolerance< 0.1 ppm
Continuous operating pH3-10
Cleaning pH2-12
Maximum element pressure drop10 psi
Technical Document
Household & High-flow Product Catalog
Download the original technical sheet used for the model data on this page.
Technical Inquiry